BE3D Repair Tips




Search: BE3D
Results 32
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Sony BE3D
Picture too big, maybe strange colors, shuts down after a few secondsCheck for shorts in IC606 9V voltage reg
Sony BE3D
Procedure to enter the service modePress standby, i, 5, vol+ and tv TT should now be displayed on the screen indicating the set is in the service mode
SonyKV28WS2U BE3D
St/by LED flashes twiceM24C32 sm EEPROM replaced (caused by crt flashover?)
SonyKV28WS2U BE3D
Service mode enteringfrom st/by press OSD/5/volume+/tv; TT____ will appear top right. Entering TT38 sets the TV as a 28 inch, TT24 sets TV as PAL I, TT79 for widescreen. MENU gives submenu choices eg geometry; TT00 exits & stores
SonyBE3D KV32WF1U
Serrated line at top & bottom of screenFit improved line driver trfmr pt no 1-437-090-31
SonyBE3D KV32WF1U
DEAD WITH POWER SUPPLY SCREAMINGREPLACE LINE O/P TRANSISTOR Q802
SonyBE3D KV32WF1
NO SOUNDREPLACE IC1200, PS602, Q1200 AND Q1201
SonyBE3D KV29F2U
Height excessive varies with pic content then collapses aft 3 mins shuts down with LED flashing error 2IC606 LM2940CT 9V regulator s/c from input to output in PSU secondary, thus the +9V line was high and varied with picture content.
SonyBE3D KV28WS2U
St/by only LED flashes error code 2LOPTx can be cause, confirmed by measuring volts coll Q606 in prot cct. If it rises to 11v LOPTx faulty (should be 0v) - then enter serv mode & disable prot (see other entry).
SonyBE3D KV28WS2U
St/by only LED flashes error code 2Instead of replacing the EEPROM try the following - Whilst LED is flashing enter serv mode (St/by, I, 5, vol+ & TV). This disables prot & set comes on with "TT--" . Press "0, 8" on R/C which will clear error buffer.
SonyBE3D KV28WS2U
LED successively flashes twiceM24C32-MW6T EPROM IC2 - 8 leg sm device pt no 875952494
SonyBE3D KV28WS2U
LED flashes twice aft LOPTx replacement to cure dead setCheck EEPROM 24C32 in IF sound module by replacement. Enter service mode & at TT promt enter country code 24 (UK system) - prevents need for setting each chan band when tuning
SonyBE3D KV28WS2U
EEPROM corruptionCaused by flashover of red gun in crt - crt replaced under warranty (if lucky)
SonyBE3D KV28WS2U
Dead at sw on - will produce a click from relay after a period of time. When G2 advanced, line collapse noticedCheck for dry joints around scan coils plug, check R870M for o/c 1R, 1w
SonyBE3D KV28WS2U
BUZZING NOISE THROUGH SPEAKERSCHECK EARTH CONNECTION ON CN303 PLUG FOR O/C OR DRY JOINT
SonyBE3D KV28WS2U
At sw on reverts to st/by with LED flashing twiceMeasure volts at collector Q606 (located in the middle of the PCB towards the right edge), if it stays at 0V, then you need to replace or re-set the EEPROM, if it goes high - then overcurrent protection is activated, suspect faulty LOPT. After replacing the LOPT, collector Q606 should stay at 0V and the set should come on, however with some software versions, the error code 2 will remain in the memory and you need to clear it manually.To clear the error code from the EEPROM you can replace it with a blank one, but it is much easier just to re-set it. While your error code 2 is still flashing, press on the remote control: [5], [-/--], [5], [9], [Standby], [i], [5], [vol+], [TV]. The set will come on in the service mode with TT-- on the screen, press [MENU] and write down all the settings for picture, geometry and sound. Then press [MENU] again to return to TT-- screen. Enter 49 to clear the EEPROM, and switch the mains off. Now go back to the service mode (TT-- on the screen), enter 24 to set destination "UK", then press [MENU] and enter all the settings what you have written down. The sequence [5], [-/--],[5],[9] sets the TV on program 59; the sequence [Standby], [i], [5], [vol+], [TV] is used to enter the service mode. In order to execute the command TT49 (re-set EEPROM), the TV must be on program 59.
SonyBE3D KV28WS2
VOLUME VARIES, CHANNELS WIPE FROM MEMORY, UNUSUAL CHARACTERS DOWN SIDE OF SCREENREPLACE IC3 WITH PREPROGRAMMED NEW TYPE
SonyBE3D KV25X1U
LED flahes 19 times at sw onMultiple devices not acknowledging - Fuse PS603 o/c
SonyBE3D KV25X1U
E/W faultyQ800 in pin cush out cct leaky
SonyBE3D KV24WX1U
Whine from lh chan over normal sound, same on phone & scart skt - RH chan okSus MSP chip IC202 on "A" board with tuner. As this is a 60 pin sm chip & expensive the good chan was linked to both o/ps